Problems and Functional Analysis Needed in LED Underwater Lamp Installation

  Author :Green earth– LED Strip Lights manufacturers

LED underwater lamps are generally LED light sources, and LEDs are called fourth-generation lighting light or green light sources, with energy saving, environmental protection, long life, small size. When it is powered, you can send a variety of colors, colorful, usually installed in the park or fountain pool.

The LED underwater lamp is a water bottom lamp produced by LED technology. Compared to traditional underwater lamps, the LED underwater lamp is more energy-saving and environmentally friendly, and the light is varied, and the decorative is stronger, which is widely used in a variety of landscape lighting systems. However, as a manufacturer of LED luminaires, some problems in the installation of the LED underwater lamp require special attention.

1. The LED underwater lamp should be powered by DC constant current power supply. Under constant current power control, the LED wall light, LED light, LED underwater lamp, LED buried lights will become small as the temperature of the LED chip is increased, so that the case is for LED underwater lamps. There is not much impact. However, if it is a constant pressure driver, the chip that causes the LED underwater lamp continuously increases the temperature rise, and it may even burn the LED underwater lamp when it is severe. Therefore, the LED underwater lamp should be powered by DC constant current power supply.

2, need to do anti-static measures. LED underwater lamp products should use certain anti-static measures during processing and installation, such as: Workbench should be grounded, workers should wear anti-static clothing, with anti-static rings, and with anti-static gloves, etc. Anti-static ion fan, but also to ensure that the air humidity in the installation is about 65%, so as to prevent the air to be too dry to produce static electricity. In addition, different quality grades of LED antistatic capacity is different, and the high-quality LED underwater lamp anti-static capacity is strong.

3. Pay attention to the seal of the LED product. No matter what kind of LED lamp products, as long as it is applied to outdoor, it faces moisture-proof, sealing problems, and the situation is even more likely to the LED underwater lamp. Sealing problems will not affect the service life of LED underwater lamp products.

1) Safety function

In the landscape, the choice of LED underwater lamps uses personal safety as the first element. The 12V voltage LED underwater lamp must be used in accordance with the requirements of the national standard.

2) Lighting function

The lighting function mainly refers to the luminance of the light source. It can choose different power LED underwater lamps according to the illumination height and the light area. Another feature of the lighting function is the color of the LED underwater lamp, which is generally red, yellow, green, blue, white, and can be used according to the application, irradiation objects and the atmosphere of creating.

3) Appearance and housing materials

Although the LED underwater lamp is used underwater, it is not very dedicated. However, the top and material is related to the specific gravity of the lamp. If the specific gravity is too small, a large buoyancy is generated, easy to loosen the fixed screw of the LED underwater lamp, so that the lamp is floating and too heavy and the lamp holder is difficult to support. At the same time, due to long-term use of water, the shell material should have a certain anti-corrosion function, and the surface lacquer is firm.

4) Economic

The economic performance of the LED underwater lamp refers to the sum of the one-time investment and operating costs of the lamp. In general, the quality is better than the LED underwater lamp. Its luminaire has a high price. It has a long service life. It has a small operating cost. It is, the quality of LED underwater lamps are poor, although the price is cheap, but often causes blindness due to leakage, leakage Not only added operational costs, and some even affect the acceptance of the entire project.

Problems and Functional Analysis Needed in LED Underwater Lamp Installation 1

GET IN TOUCH WITH Us
no data
recommended articles
News Application
About [LED Tube] Meet Common Problems, LED Flood Lights, LED Industrial Mine Lamps, LED Tubes
About [LED Tube] Meet Common Problems, LED Flood Lights, LED Industrial Mine Lamps, LED Tubes
  Author :Green earth– LED Strip Lights manufacturersAs far as the LED tube we have seen, there is a structural, internal wiring, anti-electric shock protection, insulation resistance, and electrical strength, creepage distance and electrical gap, heat resistance and refractory. Different LED tubes are different from the light source and materials that determine different price and safety, and the LED tube has a built-in power supply, and the agency different decisions is different.Century Ruiguang Company Engineering Department Li Manager's current technical security issues related to LED tubes, for the type II anti-electric shock type, requires LED tube input contact to reinforce insulation resistance and electrical strength, many built-in power transformers and LED module aluminum substrate Improper installation, causing the test to pass. Or many companies use non-separated power supplies in order to save costs and power efficiency. Internal wiring is mainly linear and insulating thickness, mechanical damage, and insulating layer. The inside is basically can't be in contact with the lamp shell of the aluminum, and the insulation is enhanced. It is also necessary to avoid internal wires and power supply directly to contact the outer casing and prevent the wire from being broken. In terms of structure, it is necessary to prevent insulation of the lamp head, screw, and contact metal surface, and the corresponding lamp head plastic should be used to prevent melting. Since the screws of the LED tube are directly locked, they are required to pay attention to the creepage distance and electrical interval. The internal power supply and the aluminum housing are needed to be separated from the insulating sleeve to reach the power level. The lamp holder and the lamp body are relatively insulated to prevent leakage of the shell.Article Source: LED tube
About [LED Tube] Industry Case, LED Industrial Mine Lamp, LED Tube, LED Spotlight
About [LED Tube] Industry Case, LED Industrial Mine Lamp, LED Tube, LED Spotlight
  Author :Green earth– LED Strip Lights manufacturersIn 2014, the LED lighting industry was not destined to be an ordinary year. Thunder X illuminated, followed by Wuhan, Hubei, after Hangzhou, Zhejiang, once again“replace”Guangdong Shenzhen operations middle candidates; Yigong and Wu Zhengzheng broke up and the goods were 120 billion to buy, the original agent will be in the question, leaving a lot of topics worthy of the illumination. BeTwenty years ago, Guangzhou, there is a group of fresh young people, we all have simple wishes, this wish is just a little bit better for the days. They stepped on classic“Phoenix”Double bar bike, the street alley is delivered by a hardware store. They grow in plain, change in growth, very fast,“After the Yangtze River”, A batch of storm-free pre-sealing, the state-owned bulb manufacturing plant falls, another batch“Unique”The private lighting company founded it, which also laid a lot of a lot of a lot of lines.Replacement brands frequently in the short term, the loss of the dealer cannot be estimated. Huizhou's potential brand West X original Nanjing agent, from the west x brand I can't promote the promotion fees, I have to light your career with him.“Puff”Break up, turn the flower light.In the transformation of China's economy, our employment is increasing, and the warehousing capital is increasing, and the delivery capital is increasing, and the manufacturer is looking for a variety of increases, and the quotation is getting more flat. Many dealers are carrying a micro profession. Selling, and even no profit sale, and even some are still being sold.Article Source: LED tube
Eight-meter Solar LED Stream Pole Strength Calculation
Eight-meter Solar LED Stream Pole Strength Calculation
  Author :Green earth– LED Strip Lights manufacturersEight-meter solar LED stream pole strength calculationThe following explanation is determined according to GB50135-2006 "Tower Structural Design Specification". Known Conditions are calculated in maximum wind speed V = 36m / s, 12 typhoon. Solar LED Street Light Bar Material Q235 Wait Stress [σ] = 225000kn / m2.Solar LED street lamp lever shape size 8m, light pole height h = 8m, wall thicknessδ5, upper mouth diameter D = 60, lower mouth diameter D = 165 . The upper part of the light pole is in the upper arm length size is l = 1.3M lamp bottom plate flange 420 ×420 .Solar LED street lamp foundation size, foundation profile 0.6m×0.6m, buried depth 1.5m, ground bolt hole distance 320 ×320 , the bolt diameter M24 is four.Solar LED street light pole strength calculation: standard wind pressure calculation, basic wind pressure is W0 = 0.8kN / m2 by wind speed 36m / s, the standard wind pressure W = W0·KT = 0.8×1.1 = 0.88kn / m2. The wind pressure adjustment coefficient KT takes 1.1.The wind calculation of the solar LED street lamp holder stroke light headμS, conical rod body 8.7 wind pressure high speed change coefficientμZ, take 0.9, the light pole is in the wind area S rod = 1.06m2, the street lamp is in the wind area S light = 0.3m2, the light rod is affected by the wind F rod = W·μYes·μexist·S rod = 0.588KN, the lamp head is affected by wind F light = W·μYes·μexist·S light = 0.166knThe total bending moment of the solar LED street lamp lever is calculated, the light pole bending moment M rod = f·H / 2 = 1.176KN·m, the lamp head to the bending moment of the pole, M light = F light·H = 1.328KN·M total bending moment,σM = M rod M lamp = 2.504 kN·NoSolar LED street light pole bending modulus calculation. WZ =πD 4—D4 / d = 3.14×(0.1654-0.1554) / 32/0.165=0.0000976m3.Calculation of solar LED street light pole bending stress. Bending stressσσ=σM / W0 = 25661.8kn / m2σσAs seen from the above calculations, the strength of the solar LED street light pole is sufficient. The geodial bolt intensity check, the wind direction is the diagonal, the tension of the terrain bolt is the maximum N =σM×Y /σY²= 2.504×0.327 / 0.327²2×0.1²= 6045KN, safety factor k take 2.5 floor bolts M24 effective cross-sectional area, s = 314 ², Q235 steel yield limit,σS = 235n / ², Licensed pull N =σYes×S / K = 235×314 / 2.5 = 295KN> n = 645KN, and the ternary bolts are more than four M24.YWX [Excellent Promotion Screen 18013196696]
no data
Green Earth is continuously approaching different markets in various ways, we will keep on researching and designing innovative products, bring a better light to human beings. 
QUICK LINK
CONTACT US

Market cooperation : Pei Yin

E-mail : greenearthcn@greenearthcn.com

Phone : +86 13823531612

Supplier Cooperation : Zhi Song

E-mail : songzhi@green-earth.cn

Phone : +86 13588306599

ADDRESS
5-7F, Block 1, Industrial Park 29, Makan Village, Xili Town, Nanshan District, Shenzhen,China. 518055
FOLLOW US
   

Copyright © 2021 GREENEARTH  |  Sitemap

chat online
Please message us and we’ll be sure to respond ASAP, what product you intrested in?